क्लिनिकल स्टडीज (नैदानिक अध्ययन)

नंगी त्वचा पर आर्टरी हीट बैलेंस थर्मोमेट्री: रोगी और चिकित्सक के लिए सटीकता,आराम और सुविधा।

There has in the past been no method of thermometry that is considered by patients and clinicians to be comfortable, convenient, and accurate. Rectal, oral, axilla, and ear thermometry all have either significant discomfort due to the use of a body cavity, artifactual inaccuracies due to physiological/device phenomena, or both, thus making them less than desirable for the needs of both patient and clinician. The exposed skin eliminates the use of a body cavity, but an accurate method using the skin has heretofore not been demonstrated.

अतीत में थर्मोमेट्री की कोई विधि नहीं रही है जिसे रोगियों और चिकित्सकों द्वारा आरामदायक, सुविधाजनक और सटीक माना जाता है। रेक्टल, ओरल, एक्सिला और ईयर थर्मोमेट्री सभी में या तो शरीर की गुहा के उपयोग के कारण असुविधा होती है, शारीरिक / उपकरण घटना के कारण कृत्रिम अशुद्धि, या दोनों, इस प्रकार उन्हें रोगी और चिकित्सक दोनों की जरूरतों को पूरा नहीं करती थी। त्वचा शरीर के गुहा के उपयोग को समाप्त करती है, लेकिन त्वचा का उपयोग करने का एक सटीक तरीका अब तक प्रदर्शित नहीं किया गया था।

सतही टेंपोरल आर्टरी त्वचा थर्मोमेट्री विधि के लिए जरूरी आवश्यकताओं को प्रदर्शित करती है: यह आसानी से सुलभ है, इसमें कोई श्लेष्म झिल्ली नहीं है, और विशेष रूप से, इसमें कोई या बहुत कम धमनीविस्फार एनास्टोमोसेस (एवीए) नहीं है। एवीए के अभाव का मतलब है कि छिड़काव दर अनिवार्य रूप से सभी परिस्थितियों में विश्वसनीय है, और थर्मोमोरेगुलेटरी उत्तेजनाओं के जवाब में रक्त प्रवाह वासोमोटर नियंत्रण से अपेक्षाकृत मुक्त है। सभी सुलभ त्वचीय रक्त वाहिकाओं पर विचार करते समय यह गुण अस्थायी धमनी के लिए अद्वितीय है। उच्च और विश्वसनीय छिड़काव त्वचीय प्रवाह के कारण पर्यावरण को खोई गई गर्मी की सटीक गणितीय गणना की अनुमति देता है, और इस प्रकार टेंपोरल आर्टरी थर्मामीटर ह्रदय के सटीक तापमान की गणना करता है। तापमान माप के लिए एक साइट के रूप में, टेंपोरल आर्टरी कई लाभ प्रस्तुत करती है: यह रोगी या चिकित्सक के लिए चोट का कोई जोखिम नहीं रखती है, किसी भी तरह की चीर-फाड़ या अनबंडलिंग की आवश्यकता को समाप्त करती है, और सभी उम्र के लिए उपयुक्त है। तदनुसार, Exergen, एक पेटेंट और हिट बैलेंस टेक्निक को शामिल करते हुए, टेंपोरल आर्टरी पर गैर-आक्रामक धमनी तापमान मूल्यांकन के लिए उपकरण विकसित किया। निम्नलिखित प्रकाशित क्लीनिकल पेपर और रिसर्च आर्टिकल इस पद्धति की वैधता का समर्थन करते हैं।

नैदानिक अध्ययन पीडीएफ डाउनलोड करें

नैदानिक सत्यापन परिणाम

पीयर-रिव्यूड प्रकाशित पेपर्स, एब्सट्रैक्ट्स, लेटर्स ऑन एक्सर्जेन टेम्पोरल आर्टरी थर्मोमेट्री 31 अक्टूबर, 2019 (कुल 87)

  1. Allegaert K, Casteels K, van Gorp I, Bogaert G. Tympanic, infrared skin,and temporal artery scan thermometers compared with rectal measurement in children: a real-life assessment.Curr Ther Res Clin Exp. 2014 May 8;76:34-8. doi: 10.1016/j.curtheres.2013.11.005. eCollection 2014.

2. Al-Mukhaizeem F, Allen U, KomarL, et al (University of Toronto/Hospital for Sick Children). Validation of the temporal artery thermometry by its comparison with the esophageal method in children. Pediatric Academic Societies Annual Meeting, May 3-6, 2003, Seattle, WA

3. Al-MukhaizeemF, Allen U, Komar L, et al (University of Toronto/Hospital for Sick Children). Comparison of temporal artery, rectal and esophageal core temperatures in children: Results of a pilot study.Journal of Pediatric and Child Health, Vol 9, No 7, pp 461-465, 2004

4. Asher C and Northington L. Position Statement for Measurement of Temperature/Fever in Children. Journal of Pediatric Nursing, Vol 23, No 3 (June), 2008

5. Artz BA, March KS, Grim RD ( WellSpan Health–York Hospital). Clinical Nurse Specialistsempowering staff to improve patient outcomes in temperature measurement: from PI/EBP to nursing research. 2011 National Association of Clinical Nurse Specialists National Conference Abstracts, March 10-12, 2011, Baltimore MD

6. Bahorski J, Repasky T, Ranner D, Fields A, Jackson M, Moultry L, Pierce K, Sandell M (Tallahassee Memorial Healthcare). Temperature measurement in pediatrics: a comparison of the rectal method versus the temporal artery method. In Press, Corrected Proof, Available online 24 February 2011, Journal of Pediatric Nursing(2011).

7. Barringer LB, Evans CW, Ingram LL, Tisdale PP, Watson SP, Janken JK (PresbyterianHospital Matthews). Agreement between temporal artery, oral, and axillary temperature measurements in the perioperative period. J Perianesth Nurs.2011 Jun;26(3):143-50.

8. Barry L, Branco J, et al. The impact of user technique on temporal artery thermometer measurements. Nursing Critical Care: September 2016 -Volume 11 -Issue 5 -p 12–14.

9. Batra P, Saha A, Faridi MM. Thermometry in children. J Emerg Trauma Shock. 2012 Jul;5(3):246-9.

10. Batra P, Goyal S. Comparison of rectal, axillary, tympanic, and temporal artery thermometry in the pediatric emergency room. Pediatr Emerg Care. 2013 Jan;29(1):63-6. doi: 10.1097/PEC.0b013e31827b5427.

11. Beedle SE, Phillips A, et al. Preventing unplanned perioperative hypothermia in children. AORN J.2017 Feb;105(2):170-183. doi: 10.1016/j.aorn.2016.12.002.

13. Bindu et al. 2015. Newborn friendly thermometry –Comparative study of body temperature with an infrared versus digital thermometer. Indian J Child Health Vol 2 | Issue 2 | Apr -Jun 2015

14. Blake S, Fries K, Higginbotham L, Lorei C, McGee M, Murray R, Priest M, Rangel J, Remick-Erickson K, Schneider L, Vodopest B, Moore A. Evaluation of noninvasive thermometers in an endoscopy setting. Gastroenterol Nurs. 2019 Mar/Apr;42(2):123-131. doi: 10.1097/SGA.0000000000000367.

15. Boland LL et al. 2016. Prehospital Lactate Measurement by Emergency Medical Services in Patients Meeting Sepsis Criteria. West J Emerg Med. (2016)

16. Bordonaro S et al. 2016. Human temperatures for syndromic surveillance in the emergency department: data from the autumn wave of the 2009 swine flu (H1N1) pandemic and a seasonal influenza outbreak

17. Bradley SL, Kwater AP, et al. Is skin temperature measurement in PACU an accurate reflection of core temperature? ASA Abstract A3182, the Anesthesiology Annual Meeting 2016, http://www.asaabstracts.com

18. Bridges E, Thomas K (University of Washington). Noninvasive measurement of body temperature in critically ill patients. Crit. Care Nurse. 2009; 29(3): p. 94-97

19. Burdjalov VF, Combs A, Nachman S, Baumgart S (SUNY at Stony Brook).Non-Invasive infrared temperature assessment of the temporal artery for core temperature determination in premature neonates, Presented American Pediatric Society and the Society for Pediatric Research, May 1, 2001.

20. Callanan D (Christus Santa Rosa Children’s Hospital). Detecting fever in young infants: reliability of perceived, pacifier, and temporal artery temperatures in infants younger than 3 months of age. Pediatr Emerg Care. 2003 Aug;19(4):240-3.

21. Calonder EM, Sendelbach S, Hodges JS, Gustafson C, Machemer C, Johnson D, Reiland L (Abbott Northwestern Hospital). Temperature measurement in patients undergoing colorectal surgery and gynecology surgery: a comparison of esophageal core, temporal artery, and oral methods. Journal of PeriAnesthesia Nursing, Volume 25,Issue 2, April 2010, Pages 71-78

22. Canales AE (Texas Tech University Health Sciences Center). OTC device: temporal scanner TAT-2000C. J Am Pharm Assoc(Wash DC). 2007 Jan-Feb;47(1):112.

23. Carleton E, Fry B, Mulligan A, Bell A, BrossartC. Temporal artery thermometer use in the prehospital setting. Canadian Journal of Emergency Medicine2012;14(1):7-13.

24. Carr EA, Wilmoth ML, Eliades AB, Baker PJ, Shelestak D, Heisroth KL, Stoner KH (Akron Children’s Hospital). Comparison of Temporal Artery to Rectal Temperature Measurements in Children Up to 24 Months, Journal of Pediatric Nursing, In Press, [Epub ahead of print], Jan 25, 2010.

25. Carroll D, Finn C, Gill S, et al (Massachusetts General Hospital). A comparison of measurements from a temporal artery thermometer and a pulmonary artery catheter thermometer. Am J Crit Care. 2004;13:258.

26. Chiu SH, Anderson GC, BurkhammerMD (University of Akron/Case Western Reserve University). Newborn temperature during skin-to-skin breastfeeding in couples having breastfeeding difficulties. Birth. 2005 Jun;32(2):115-21.

27. Crossley B. Blanket warmers revisited and temporal thermometers. Biomedical Instrumentation and Technology, March/April 2012 p147.

28. Dybwik K, Nielsen EW. Infrared temporal temperature measurement. Journal of the Norwegian Medical Association 2003; 123: 3025-6.

29. Espenhein A (County Hospital in Herlev, Denmark). Temporal temperature measurement. Sygeplejersken2006;(17):50-2.

30. Fetzer SJ, Lawrence A (Southern New Hampshire Medical Center). Tympanic membrane versus temporal artery temperatures of adult perianesthesia patients. J Perianesth Nurs.2008 Aug;23(4):230-6.

31. Foy S, McGillicuddy D, Pompei F, Sanchez L (Beth Israel Medical Center, Boston MA). Body Temperature Surveillance and Reporting in the Emergency Department: A Practical Sentinel for Pandemics and Bioterrorism. Presented at Society for Academic Emergency Medicine Annual Meeting, Phoenix AZ , June 3-6, 2010.

32. Fratto L, Hogan K, Kenney K. Temporal artery thermometry use in pediatric patients in the post-anesthesia care unit. 2012 Research and EBP Abstracts ASPAN’s 31st National Conference April 15-19, 2012, Orlando, FL Inf…2012 Research and EBP Abstracts -8/1/2012 12:43:08 PM.

33. Furlong D, Carroll D, Finn C, Gay D, Gryglik C, Donahue V (2015). Comparison of Temporal to Pulmonary Artery Temperature in Febrile Patients. Dimensions of Critical Care Nursing. 2015 Jan-Feb; 34(1):47-52. doi: 10.1097/DCC.0000000000000090.

34. Greenes DS, Fleisher GR. (Boston Childrens Hospital and Harvard Medical School). Accuracy of a noninvasive temporal artery thermometer for use in infants. Arch Pediatr Adolesc Med, Vol 155, pp 376-381, Mar 2001

35. Greenes DS, Fleisher GR. (Boston Childrens Hospital and Harvard Medical School). When body temperature changes, does rectal temperature lag?Journal of Pediatrics, 02.037, pp 824-826, September 2004.

36. Gunawan M, Soetjiningsih I ( Udayana University, Sanglah Hospital, Denpasar, Indonesia). Comparison of the accuracy of body temperature measurements with temporal artery thermometer and axillary mercury thermometer in term newborns.Paediatr Indones, Vol. 50, No. 2, March 2010.

37. Haddad, L., Smith, S., Phillips, K.D., and Heidel, R.E. (2012). Comparison of temporal artery and axillary temperatures in healthy newborns. Journal of Obstetric, Gynecologic, & Neonatal Nursing, 41, 383-388; doi: 10.1111/j.1552-6909.2012.01367.x

38. Harding C, Pompei F, Bordonaro SF, McGillicuddy DC, Burmistrov D, Sanchez LD. 2019. The daily, weekly, and seasonal cycles of body temperature analyzed at large scale. Chronobiol Int. 2019 Sep 17:1-12. doi: 10.1080/07420528.2019.1663863. [Epub ahead of print]

39. Hargreaves L. (2017) Toolkit for implementation of temporal artery thermometers for neonates. ProQuest Number 10603156, Published by ProQuest LLC (2017)

40. Harper CM ( Royal Sussex CountyHospital Brighton, UK). The need for an accurate noninvasive thermometer. Anesth Analg. 2009 Jul;109(1):288; author reply 288-9.

41. Hayes K, Shepard A, Cesarec A, et al. Cost minimisation analysis of thermometry in two different hospital systems. Postgrad Med J Published Online First: 18 January 2017, doi:10.1136/postgradmedj-2016-134630

42. Health Canada (2017). Summary Safety Review -Ear and Forehead (contact) InfraredThermometers (various brands) – Assessing the potential risk of inaccuracy in children under 2 years old. https://www.canada.ca/en/health-canada/services/drugs-health-products/medeffect-canada/safety-reviews/summary-safety-review-forehead-contact-infrared-thermometers-various-brands-assessing-potential-risk-inaccuracy-children-under-2-years-old.html

43. Hebbar K, Fortenberry JD, Rogers K, Merritt R, Easley K. (Children’s Healthcare of Atlanta at Egleston). Comparison of temporal artery thermometer to standard temperature measurements in pediatric intensive care unit patients. Pediatr Crit Care Med. 2005 Sep;6(5):557-61.

44. Honaker et al 2018. Monitoring Temperature: Knowledge and skills of outpatients with cancer. CLINICAL JOURNAL OF ONCOLOGY NURSING DECEMBER 2018, VOL. 22 NO. 6

45. Hughes D. Study recommends use of professional temporal thermometer in adults. Oncology Nurse AdvisorApril 27, 2013.

46. Hurwitz B1, Brown J, Altmiller G. Improving pediatric temperature measurement in the ED.Am J Nurs. 2015 Sep;115(9):48-55. doi:10.1097/01.NAJ.0000471249.69068.73.

47. Isler, A., et al. Comparison of temporal artery to mercury and digital temperature measurement in pediatrics. Int. Emerg.Nurs. (2013), http://dx.doi.org/10.1016/j.ienj.2013.09.003

48. Kirk D, Rainey T, Vail A, Childs C (University of Manchester, Salford Royal Foundation Trust). Infra-red thermometry: the reliability of tympanic and temporal artery readings for predicting brain temperature after severe traumatic brain injury. Crit Care. 2009 May 27;13(3):R81. [Epub ahead of print]

49. Kumana C. Minimisingthe costs of temperature monitoring in hospitals. Postgrad Med J Published Online First: 1 February 2017 doi:10.1136/postgradmedj-2017-134795

50. Kurnat-Thoma E, EdwardsV, EmeryK. Axillary, tympanic, and temporal thermometry comparison in a community hospital pediatric unit.-PEDIATRIC NURSING/September-October 2018/Vol. 44/No. 5

51. Langham GE, Maheshwari A, Contrera K, You J, Mascha E, Sessler DI (Case Western Reserve University). Noninvasive temperature monitoring in postanesthesia care units. Anesthesiology, V 111, No 1, Jul 2009

52. Lawson L, Bridges E, Ballou I, Eraker R, Greco S, Shively J, Sochulak V. (University of Washington). Temperature measurement in critically ill adults. Am. J. Crit. Care., May 2006; 15: 324 -346.

53.Lawson L, Bridges E, Ballou I, Eraker R, Greco S, Shively J, Sochulak V. (University of Washington). Accuracy and precision of noninvasive temperature measurement in adult intensive care patients. Am. J. Crit. Care., Sep 2007; 16:5, 485-496.

54. Lee G, Flannery-Bergey D, Randall-Rollins K, Curry D, Rowe S, Teague M, Tuininga C, Schroeder S (Exempla Lutheran Medical Center).Accuracy of temporal artery thermometry in neonatal intensive care infants.Advances in Neonatal Care, Vol. 11, No. 1, pp. 62-70, Feb2011.

55. Makic MB, VonRueden KT, Rauen CA, Chadwick J. Evidence-based practice habits: putting more sacred cows out to pasture. Crit Care Nurse.2011 Apr;31(2):38-61; quiz 62.

56. Martinez EA, Krenzischek D, Hobson D, Hunt D (Johns Hopkins Medical Institutions). The structure and processes of care delivery impact postoperative normothermia. Anesthesiology2007; 107: A496.

57. Mason TM, Reich RR, et al. Equivalence of temperature measurement methods in the adult hematology/oncology population. Clin J Oncol Nurs. 2015 Apr;19(2):E36-40. doi: 10.1188/15.CJON.E36-E40.

58. McConnell E, Senseney D, George S, Whipple D. Reliability of temporal arterythermometers. Medsurg Nursing2013, Nov-Dec 2013, Vol. 22/No. 6, p387

59. McGrory2018. Letter to the Editor on “Hypothermia in Total Joint Arthroplasty: A Wake-Up Call”. The Journal of Arthroplasty 33 (2018) 3056e3059.

60. Merrill, K. (Seattle Children’s Hospital). Comparison of temporal artery temperature m easurement with standard temperature measurement in critically ill children. American Journal of Critical Care. 2014, May, 23(3), e23.

61. Moore AH, Carrigan JD, Solomon DM, Tart RC. Temporal artery thermometry to detect pediatric fever. Clin Nurs Res. 2015 Oct;24(5):556-63.doi: 10.1177/1054773814557481. Epub 2014 Nov 14.

62. Myny D, DeWaele J, Defloor T, Blot S, Colardyn F (Ghent University Hospital, Ghent, Belgium). Temporal scanner thermometry: a new method of core temperature measurement in intensive care patients. SMJ 2005 45(1): 15-18.

63. Opersteny, Esther et al. Precision, sensitivity and patient preference of non-invasive thermometers in a pediatric surgical acute care setting. Journal of Pediatric Nursing: Nursing Care of Children and Families , 2017, Volume 35 , 36 –41.

64. Pappas M. Understanding the different methods for taking a temperature. NASN School Nurse 2012 27: 254 originally published online 5 July 2012.

65. Park et al. 2018. Diagnostic Accuracy of Temporal Artery Temperatures Measurements. Journal of Korean Clinical Nursing Research Vol.24 No.2, 227-234, August 2018

66. Paul IM, Sturgis SA, Yang C, Engle L, Watts H, Berlin CM Jr (Penn State College of Medicine). Efficacy of standard doses of Ibuprofen alone, alternating, and combined with acetaminophen for the treatment of febrile children. Clin Ther. 2010 Dec;32(14):2433-40.

67. Pittman R and Waters R (CaroMontHealth Care, Gastonia, NC). Do our patients have hypothermia? Temporal versus oral thermometers. Journal of PeriAnesthesia NursingVolume 24, Issue 3, June 2009, Page e18.

68. Pompei F, Pompei M. Non-invasive temporal artery thermometry: Physics, Physiology, and Clinical Accuracy, presented at Medical Thermometry for SARS Detection, SPIE Defense and Security Symposium, available in Conference Proceedings,April, 2004.

69. Pompei F. Insufficiency in thermometer data. Anesth Analg.2003 Mar;96(3):908-9.

70. Pompei F. RE: A brief report on the normal range of forehead temperature as determined by noncontact, handheld, infrared thermometer. Am J Infect Control.2006 May;34(4):248-9.

71. Pompei F. Misguided guidelines on noninvasive thermometry. Crit Care Med.2009 Jan;37(1):383; author reply 383-4.

72. Qadir 2019. How normal body temperature relevance with falooda ice cream loving. MOJ Food Processing & Technology. April 5, 2019

73. Reynolds M, et al. Are temporal artery temperatures accurate enough to replace rectal temperature measurement in pediatric ED patients? J Emerg Nurs. 2012 Nov 8. pii: S0099-1767(12)00329-7. doi: 10.1016/j.jen.2012.07.007. [Epub ahead of print]

74. Rollins K, Flannery-Bergey D. Accuracy of temporal artery thermometry in neonatal intensive care unit infants. JOGNN, 40, S85-S119; 2011. DOI: 10.1111/j.1552-6909.2011.01243.x

75. Routhier D, Hostler D, Wolfson A, Wheeler M, Reynolds J (University of Pittsburgh). Comparison of temporal artery and oral temperatures in the emergency department. ACAD EMERG MED, May 2006, Vol. 13, No. 5, Suppl. 1, www.aemj.org, p. S99

76. Roy S, Powell K, Gerson LW (Akron Children’s Hospital). Temporal artery temperature measurements in healthy infants, children, and adolescents. Clinical Pediatrics, pp 433-437, June 2003.

77. Sandlin D (Southern Hills Medical Center, Nashville TN). New Product Review: Temporal Artery Thermometry, Journal of PeriAnesthesia Nursing,Vol. 18, No 6 (December) 2003, pp 419-421.

78. Schuh S, Komar L, StephensD, Chu L, Read S, Allen U (University of Toronto/Hospital for Sick Children). Comparison of the temporal artery and rectal thermometry in children in the emergency department.Pediatric Academic Societies Annual Meeting, May 3-6, 2003, Seattle, WA.

79. Schuh S, Komar L, Stephens D, Chu L, Read S, Allen U (University of Toronto/Hospital for Sick Children). Comparison of the temporal artery and rectal thermometry in children in the emergency department.Pediatric Emergency Care,Vol 20, No. 11, Nov 2004

80. Siberry GK, Diener-West M, Schappell E, Karron RA (Department of Pediatrics, School of Medicine, The Johns Hopkins University). Comparison of temple temperatures with rectal temperatures in children under two years of age. Clinical Pediatrics, pp 405-414, July/August 2002.

81. Smith et al. Comparison of axillary and temporal artery thermometry in preterm neonates. J Obstet Gynecol Neonatal Nurs. 2018 Apr 3. pii: S0884-2175(18)30052-2. doi: 10.1016/j.jogn.2018.02.013. [Epub ahead of print]

82. Sugiarty 2018. Non-Invasive Thermometer: Temporal Artery Thermometer (TAT) Integrated with Electronic Medical Record as the Top-Ranking Temperature Measurement Method for Infants and Children. Health JournalVolume 9, Number 1, April 2018 ISSN 2086-7751 (Print), ISSN 2548-5695 (Online) http://ejurnal.poltekkes-tjk.ac.id/index.php/JK

83. Stern 2018. Taking the temperature of clinical efficiency. Biomedical Instrumentation and Technology. January/February 2018

84. Szmuk P, Curry BP, SheeranPW, Farrow-Gillespie AC, Ezri T (UT Southwestern and Children’s Medical Center, Dallas, Texas).Perioperative temperature audit in a large pediatric hospital. Anesthesiology 2007; 107: A1612.

85.Tan GM, Galinkin JL, Pan Z, Polaner DM. Laryngeal view and temperature measurements while using the perilaryngeal airway (Cobra-PLUS™) in children. Pediatric Anesthesia2013, Dec; 23(12):1180-6. doi: 10.1111/pan.12266. Epub 2013 Sep 25.

86.Titus MO, Hulsey T, Heckman J, Losek JD (Medical University of South Carolina and Children’s Hospital). Temporal artery thermometry utilization in pediatric emergency care. Clinical Pediatrics, Mar 2009; vol. 48: pp. 190 -193.

87.Yang WC, Kuo HT, et al.Tympanic temperature versus temporal temperature in patients with pyrexia and chills.Medicine (Baltimore). 2016 Nov;95(44):e5267.

hi_INहिन्दी